Skip to main content

Swedish researchers test Li-ion batteries to destruction

Researchers at Sweden’s SP Fire Research are involved in a project to develop safer battery systems for electrified vehicles, together with Atlas Copco, Chalmers University of Technology and Elforsk, with financial support from the Swedish Energy Agency. Lithium-ion batteries (Li-ion) offer great energy and power densities accompanied with long battery life time. In an abuse situation however, e.g. in case of mechanical deformation or overheating, the flammable electrolyte of the Li-ion battery might pos
October 16, 2015 Read time: 2 mins
Researchers at Sweden’s SP Fire Research are involved in a project to develop safer battery systems for electrified vehicles, together with Atlas Copco, Chalmers University of Technology and Elforsk, with financial support from the Swedish Energy Agency.

Lithium-ion batteries (Li-ion) offer great energy and power densities accompanied with long battery life time. In an abuse situation however, e.g. in case of mechanical deformation or overheating, the flammable electrolyte of the Li-ion battery might pose a risk.

The project includes various destructive tests on commercial Li-ion battery cells to study the cell response in terms of temperature, gas, fire and explosion in electrical abuse tests including overcharge and short circuit tests and exposure to fire.

SP believes that today there are no intrinsically safe Li-ion cells with usable properties. Experience from the consumer market shows that there is a small probability (ppm-level or less) for internal short circuiting in Li-ion cells, potentially resulting in a so called thermal runaway and a battery fire. In a large battery pack, with many cells, the probability of a thermal runaway will increase due to the use of more cells. This leads to an increased risk of a cell safety incident and it is important to minimise its consequences. For example, the cell-to-cell propagation of a thermal runaway in a single cell can be affected by battery pack design.

The tests showed that higher battery electrical charge level (state-of-charge) gives a higher heat release rate (HRR) while the total heat release (THR) is roughly the same for all charge levels. Gas emissions were also measured. The Li-ion cell contains fluorine that can form highly toxic compounds such as hydrogen fluoride (HF) that can be released.

Tests were also carried out using simulation tools to model the heat transfer in a pack of five cells with the aim of predicting the cell-to cell heat spread for a five-cell-pack. Using the Finite-Element software Comsol Multiphysics, the results corroborated those obtained from the experimental tests.

Related Content

  • September 10, 2014
    Toshiba introduces new super charge ion battery
    Electricity is in the air – and in Toshiba’s new super charge ion battery (SCiB), on display at ITS World Congress. SCiB batteries can be charged in five to 10 minutes, compared with the traditional overnight charging required for applications such as electric buses. SCiB charges even faster than current fast charge batteries, which take 30 minutes. The ultra-fast charging is possible because SCiB can tolerate a high current of 400 amps, almost three times higher than today’s normal fast charging batt
  • April 17, 2012
    Potential to charge an EV in minutes claim
    The University of Illinois at Urbana-Champaign has entered into a licensing agreement with Xerion Advanced Battery Corp. under which Xerion has the exclusive right to bring the University’s StructurePore battery-charging technology to the market. The StructurePore technology was developed by Paul Braun, Ph. D., of the Department of Materials, Science & Engineering at the University of Illinois, who is presently also an officer and director of Xerion. He and his colleagues believe that the StructurePore tech
  • January 10, 2013
    EU research develops method for evaluating critical infrastructure
    The European Commission’s SeRoN research project has drawn to a close, having developed a sophisticated method of identifying and quantifying threats to critical infrastructure. In December 2008 the European Commission published the directive 2008/114/EC on the identification, designation and assessment of the need to improve ‘European critical infrastructure’. In line with the objectives formulated in this directive, the SeRoN (Security of Road Transport Networks) research project was established in Novemb
  • December 5, 2018
    Safety issues fuel interest at PIARC’s tunnel conference in Lyon
    1999’s fatal Mont Blanc fire means safety is a constant concern for tunnel operators. Alternative fuels and automated vehicles were also high on the agenda at PIARC’s first conference on the issue. David Arminas reports from Lyon – and walks the Croix-Rousse tunnel More than ever, tunnel management must be done in a holistic fashion. That was the message from André Broto, president of the World Road Associa-tion (PIARC) as he kicked off PIARC’s first International Conference on Tunnel Operations and Safe