EDI launches new MMU2 SmartMonitor series

Recently launched by Eberle Design (EDI) the MMU2-16LEip and MMU2-16LE SmartMonitors fully comply with the recently updated NEMA TS2-2003 (R2008) Standard for Traffic Controller Assemblies, Amendment No. 4-2012. This new standards update defines Flashing Yellow Arrow (FYA) operation for both the controller unit and the MMU. EDI says it is also very proud to be the first MMU manufacturer to be fully conformant to the new NEMA standard and MUTCD requirements. The new SmartMonitor series is designed to monitor
December 12, 2012 Read time: 3 mins
Recently launched by 41 Eberle Design (EDI) the MMU2-16LEip and MMU2-16LE SmartMonitors fully comply with the recently updated NEMA TS2-2003 (R2008) Standard for Traffic Controller Assemblies, Amendment No. 4-2012. This new standards update defines Flashing Yellow Arrow (FYA) operation for both the controller unit and the MMU. EDI says it is also very proud to be the first MMU manufacturer to be fully conformant to the new NEMA standard and MUTCD requirements.

The new SmartMonitor series is designed to monitor an intersection with up to four approaches using the four section FYA movement outlined by the MUTCD 2009. For monitoring purposes an FYA approach is logically defined as a four input channel consisting of the solid red arrow, solid yellow arrow, flashing yellow arrow (permissive), and solid green arrow (protected). Twelve cabinet modes are now supported in the SmartMonitor providing configuration choices based on the number of load switches provided and the capabilities of the controller unit. In all modes the new MMU2-16LEip and MMU2-16LE SmartMonitors have been designed to provide the same broad fault coverage for the FYA approaches as it does for conventional protected left turn phases including conflict, red fail, dual indication, and both minimum yellow and minimum yellow plus red clearance monitoring.

The MMU2-16LE SmartMonitor series includes a built-in setup wizard to quickly and accurately configure the monitor programming parameters simply by answering a short series of questions related to the intersection geometry and cabinet wiring. The built-in context sensitive help system and patented diagnostic wizard then automatically pinpoints faulty signals, providing technicians with an unprecedented amount of assistance and data feedback quickly with a push of the help button. The SmartMonitor menu driven operation presents signal voltages, data logs and vital cabinet information displayed directly on the SmartMonitor front panel displays. These advanced capabilities will increase the operational level of safety of the intersection and enhance the diagnostic features available.

The Final Rule edition of the FHWA MUTCD 2009 manual included revised Sections 4D.17 thru 4D.24, with new sections and figures for modes of left-turn and right-turn signal operations. This development left users and equipment manufacturers with a need for an updated NEMA equipment standard in order to have equipment interchangeability and interoperability when deploying intersections using the flashing yellow arrow signals. The recent standards update from NEMA provides a number of improvements to the TS2-2003 version. Most important is the long awaited Flashing Yellow Arrow operation. Equipment standards such as NEMA TS-2 are vital to users to ensure that traffic control equipment is both interchangeable and interoperable and thus provides a long service life.

Related Content

  • SESA completes implementation of New Hampshire weigh station signs
    November 4, 2016
    SES America (SESA) and its partners New England Traffic Solutions and New England Signal Systems recently completed testing and commissioning of solar powered signs for several weigh stations in New Hampshire. These are installed on the northbound and southbound I-93 near Windham, NH and will be used to display the open/closed status of weigh stations on the highway. SESA provided the latest model of its energy-efficient blank out signs as part of the project, along with a complete solar power system tha
  • Conflict monitoring systems for lane control sign applications
    November 27, 2014
    Messaging solutions provider SESA recently signed an agreement to develop NTCIP compliant lane control signs (LCS) incorporating a conflict monitoring system as a vital design criterion. This system will automatically change lane signals that correspond to the counter flow mandate. In multi-lane counter flow commute lanes, if a green arrow is displayed on one LCS, the LCS on its reverse must display a red cross. Timing on all LCS signs will be identical. Additionally flashing red crosses will be in
  • Prowag signals change to vision statement
    February 15, 2024
    New pedestrian signal requirements designed to make crossings safer for the visually impaired mean that accessible signals are no longer just an option for US cities and municipalities. They now have the backing of the law, explains Andrew Stone
  • McCain debuts new ATC cabinet
    August 6, 2013
    Developed to meet the needs of today's modern transportation industry, McCain claims its new traffic controller cabinet design, the ATC cabinet, increases driver and personnel safety, enhances overall operations and provides a viable migration path to low-voltage intersections. The rack-mount modular cabinet with serial connections brings together the best of existing standards and incorporates National Electrical Codes (NEC) or NFPA 70 standards to guard against accidental electrocution due to inadvertent